Insulated tubes
Detailed description
These tubes have several advantages: : Worker protection, weather resistance, continuously insulated antifreeze, lightweight and flexible for easy handling, reduced installation, maintenance, repair, and space costs• Coil tube feeding minimizes the CONNECTION of the FITTING
specifications :
Generally, insulation/insulation material made of non-absorbent fibers encloses the tube bundles and protects them with various coating materials at the customer's request. Mainly installed on hot liquid, gas and steam/condensate transport lines.Specific characteristics of the components :
- Tube: Provide different materials and sizes according to the conditions and requirements of the process
- The excessive curve: Ensuring long-term safety by preventing outside humidity and cold air from entering the insulation layer
- Heating/insulating material: High-quality E-grade fiberglass and aerosol insulation is integrated to minimize heat loss and have the same thermal and insulating effect even if physical forces such as deflection and twisting are applied during installation.Related business areas :
Geothermal energy, steam tracing, process and analysis lines, creation of underground circuits or in aggressive environmentsTesting and packaging
1. Perform (prior to shipment) a pneumatic inspection, (if required) a hydraulic inspection and a non-destructive inspection
2. Authenticate most classification approvals (ABS, BV, CCS, CCS, DNV/GL, KR, LR, NK, RMRS, RINA)
3. Provide a 3-way inspection and a TEST REPORT when required by the customer
4. Length and delivery date required by the customer and supply of packaging in wooden barrels/pallets
Dimensional ranges available
Product information
- Simple, fast, economical and efficient heat transfer compared to conventional piping and thermal work
- Accelerate installation costs, speed up time, and reduce footprint by replacing steam supply and condensate recovery lines in steam trace systems in petrochemical industries and refineries.
- Provides weather protection and worker protection
- The temperature inside the treatment tube is 204°C (400°C) and the maximum temperature on the coating surface is 58°C (136.4°C) or lower during operation.
- The temperature of the internal fluid of the treatment tube can be produced at the request of the customer · Depending on the size and material of the tube, the delivery length varies and can be up to 1000M.
Outer sheath
HR-PVC and TPU
Thermal reflective tape
Aluminum sheet
Heating/insulating material
- Use E-grade non-absorbent inorganic fiberglass with a water-soluble chloride concentration of less than 100ppm when the fluid temperature inside the tube is below 300℃.
- If the process temperature is above 400℃, the use of aerosols is recommended.- The maximum allowable temperature of class E fiberglass is 649℃ (1200°F).
Treatment tube
- Standard material: 304, 316/316L stainless steel welding pipe or seamless pipe, copper pipe, Teflon pipe
- Outer tube diameter range: 6-20mm or 1/4-3/4"
Product information
STEAM TRACED HEATING TUBE (LIGHTWEIGHT)
But
For frost protection and crystallization prevention (viscosity reduction)
Structure
No contact between the tracker and the treatment tube
Maximum exposure temperature
204 °C (400 °F)
Use the line
Approximately 60% of the temperature of the steam supplied to the trace line is transmitted to the treatment tube.
- Treatment lines, pressure lines and instrumentation lines - Water or public transport lines
- Paraffin or paraffin oil lines
- Chemical lines sensitive to temperature
Tube material | Outside diameter | Wall thickness |
---|---|---|
10:316/316L SS Seamless | “1/4”: 14" | “0.035"”: 35" |
11:316/316L SS Welded | “3/8"”: 38" | “0.049"”: 49" |
20:304/304L SS Seamless | “1/2"”: 12" | “0.065"”: 65" |
21:304/304L SS Welded | “5/8"”: 58" | 0.8mm: 08 |
40: Copper | 6 mm: M6 | 1.0mm: 10 |
40: Tefron | 8mm: M8 | “1 |
10mm: M10 | 1.5:15 | |
12mm: M12 | ||
15mm = M15 |
Symbol | Selection | Symbol |
---|---|---|
* | Tube Material | P) 10/T) 30 |
** | Tube Outer Diameter | P) 38/T) 38 |
*** | Tube thickness | P) 35/T) 35 |
# | Tube | 2 |
**** | Exterior material | 1 |
***** | Coat color | 1 |
Product information
STEAM TRACED HEATING TUBE (HEAVY)
But
For temperature maintenance and steam drain lines
Structure
Direct contact between the tracker and the treatment tube
Maximum exposure temperature
204 °C (400 °F)
Use the line
Pass approximately 90% of the temperature of the steam supplied to the trace line to the process tube
- Pressure transmission line
- Analyst sample line
- High temperature steam
Tube material | Outside diameter | Wall thickness |
---|---|---|
10:316/316L SS Seamless | “1/4”: 14" | “0.035"”: 35" |
11:316/316L SS Welded | “3/8"”: 38" | “0.049"”: 49" |
20:304/304L SS Seamless | “1/2"”: 12" | “0.065"”: 65" |
21:304/304L SS Welded | “5/8"”: 58" | 0.8mm: 08 |
40: Copper | 6 mm: M6 | 1.0mm: 10 |
40: Tefron | 8mm: M8 | “1 |
10mm: M10 | 1.5:15 | |
12mm: M12 | ||
15mm = M15 |
Symbol | Selection | Symbol |
---|---|---|
* | Tube Material | P) 10/T) 30 |
** | Tube Outer Diameter | P) 38/T) 38 |
*** | Tube thickness | P) 35/T) 35 |
# | Tube | 2 |
**** | Exterior material | 1 |
***** | Coat color | 1 |
Product information
TRACED ELECTRIC HEATING TUBE — TYPE F
But
Frost prevention
Structure
Bundle with integrated magnetic control output cable
Maximum exposure temperature
-60~120°C
Use the line
- Low temperature electrical trace line, process pipes, pressure pipes
- Frost prevention or low temperature maintenance
- See the details of the ETF TYPE order method
Tube material | Outside diameter | Wall thickness | Outer shealth material | Shealth Color |
---|---|---|---|---|
10:316/316L SS Seamless | 1/4”: 14 | 0.035"”: 35" | 01: HR-PVC | 01: black |
11:316/316L SS Welded | 3/8": 38 | 0.049"”: 49" | 02: HFFR-TPU II | 02: red |
20:304/304L SS Seamless | 1/2": 12 | 0.065"”: 65" | 03: blue | |
21:304/304L SS Welded | 5/8": 58 | 0.8mm: 08 | ||
40: Copper | 6 mm: M6 | 1.0mm: 10 | ||
40: Tefron | 8mm: M8 | 2mm: 12 | ||
10mm: M10 | 1.5mm: 15 | |||
12mm: M12 | ||||
15mm = M15 |
Symbol | Selection | Symbol | Process tube |
---|---|---|---|
* | Tube Material | P) 10/T) 30 | P: tefron/H: Self-regulating |
** | Tube Outer Diameter | P) 38/T) 38 | P: 1/2" H: 240V |
*** | Tube thickness | P) 35/T) 35 | P: 0.049"/H: 8Wft (26W/m) |
# | Tube | 2 | 2 tube |
**** | Exterior material | 1 | HFFR-TPU |
***** | Coat color | 1 | Black |
Product information
STEAM TRACED HEATING TUBE (HEAVY)
But
For temperature maintenance and steam drain lines
Structure
Direct contact between the tracker and the treatment tube
Maximum exposure temperature
204 °C
Use the line
Pass approximately 90% of the temperature of the steam supplied to the trace line to the process tube
- Pressure transmission line
- Analyst sample line - High temperature steam line
Quotation within 24 hours for stock.
Specific products: quotation within 3 to 5 days.
INOXTUBE commitments
Effectiveness
500 references, from all over the world
Rapidity
Response within 48 hours
Quality
ISO 9001 certified
International
European and global transport and supply
FAQs about our products
Discover the many advantages of our product or service.
The term "hypertempered" can be misleading. For stainless steel, it means the tube has undergone a heat treatment to make it more malleable.
Contrary to popular belief, stainless steel is more resistant to rust than regular steel, but it can still rust due to external factors like mechanical or chemical exposure.
Generally, the permissible pressure is inversely proportional to the operating temperature. You can refer to our tables in our brochure or the technical part of the site for more details.